What Is an Energy Code?

Last reviewed: September 2026

An energy code is the minimum efficiency the law requires for a building's envelope, lighting, and mechanical systems. In much of the United States the adopted model is the International Energy Conservation Code, sometimes with ASHRAE 90.1 as a compliance path. A green rating program is voluntary. The energy code is a permit requirement.

1234567ABCOFFICE401OFFICE402OFFICE403OFFICE404OFFICE405OPEN OFFICE406CONFERENCE407CONFERENCE408OPEN OFFICE409OPEN OFFICE410STAIRS2TRAVEL 148'-0" < 250'-0"OL 6OL 6OL 12OL 12OL 12OL 24OL 6EXITFEC1-HOUR FIRE BARRIEREXIT ACCESS TRAVEL PATH27'-3"27'-0"27'-3"27'-3"27'-0"27'-3"94'-8"1ALIFE SAFETY PLANSCALE: 1/8" = 1'-0"N1234CONSULTING ENGINEERSREVISIONSPROJECTHARBOR POINT OFFICESSCALE1/8" = 1'-0"DATE07/18/2026KEY PLANSHEET TITLELIFE SAFETY PLANSHEET NUMBERG-101

What you're looking at

Life Safety Plan, annotated

A life safety plan with rated walls, occupant loads, and the exit access path checked against the travel limit.

  1. 1Rated corridor walls
  2. 2Exit access path with travel distance
  3. 3Exit sign at the stair
  4. 4Occupant load per room
Purpose
Minimum energy efficiency required by law
Common model
IECC, with ASHRAE 90.1 as a frequent path
Covers
Envelope, lighting, and mechanical systems
Shown by
Drawings plus a compliance report or forms
Not
A voluntary certification such as a green rating
Breaks when
Products change without updating the model

Definition

Energy code

The drawings and a compliance report show how the project meets the adopted edition: insulation, glazing U-factor and SHGC, lighting power, and HVAC efficiency. The plans examiner reviews that package. Substituting a window or a light fixture after permit can break the compliance model. California's Title 24 and other state codes replace or amend the IECC. Use the code the jurisdiction adopted, including the year. An old report on a new edition is not compliance.

In depth

The year is part of the code

Cities adopt an edition, often with amendments. A report run on the wrong year will not match plan check. State the edition on the code sheet.

Stretch codes and local green ordinances can sit on top. Ask before you assume the model code is the whole requirement.

Prescriptive or performance

Prescriptive compliance follows tables: maximum U-factors, maximum lighting power. Performance compliance uses a model that trades measures and still beats a baseline. The report should say which path. Submittals have to match the measures the path used.

COMCheck, or the state's own software, is a method. It is not the code.

The schedule is the energy model

Window schedules that list U-factor and SHGC, lighting schedules that list wattage, and mechanical schedules that list efficiency are how the report stays true. A cut sheet that misses those numbers is a compliance problem, not only a product-data problem.

Value engineering a glazing product after permit requires a new report if the numbers change.

Some codes require proof it was built

Commissioning and testing of controls show up in later editions for certain systems.

That is a closeout requirement tied to the energy code, specified so the contractor prices it.

Examples

Energy code on a real project

  • 01

    The permit set includes an IECC report for the adopted edition. The window schedule lists the U-factors the report used.

  • 02

    A lighting substitution lowers fixture wattage. The compliance form is updated anyway, because the examiner asked for the as-designed numbers.

  • 03

    A California project uses Title 24 forms. An IECC report is not substituted.

FAQ

Frequently asked questions

It is the legally adopted minimum for building energy efficiency, covering envelope, lighting, and HVAC. Compliance documents are part of the permit.

The International Energy Conservation Code, a model energy code many U.S. jurisdictions adopt, often with amendments. The adopted edition is the one that applies.

No. A voluntary rating is a program the owner chooses. The energy code is mandatory. A building can be permitted and still not hold a voluntary label, and a label does not replace the permit forms.

The design professionals prepare the documents and the compliance report. The contractor builds and submits products that match them. The plans examiner reviews the permit package.