AEC definitions

What Is a Lateral Force Resisting System?

Last reviewed: November 2026

A lateral force resisting system is the set of structural elements, such as shear walls, braced frames, and moment frames, that carries horizontal loads from wind and earthquakes through the building to the foundation. The gravity system carries vertical loads, and the lateral system keeps the building from racking or overturning.

1234567ABCW18x35W18x35W18x35W14x2218K5 @ 5'-0" O.C.TOP OF STEEL EL. 128'-6" | 3" COMPOSITE DECK + 3-1/4" LW CONC.27'-3"27'-0"27'-3"27'-3"27'-0"27'-3"94'-8"1AFRAMING PLANSCALE: 1/8" = 1'-0"N1234CONSULTING ENGINEERSREVISIONSPROJECTRIVERSIDE HOTELSCALE1/8" = 1'-0"DATE11/25/2026KEY PLANSHEET TITLEFRAMING PLANSHEET NUMBERS-201

What you're looking at

Framing Plan, annotated

A structural framing plan with columns on the grid, girders, infill beams, and the lateral system.

  1. 1Steel column at each grid intersection
  2. 2Girder on the grid line, sized on plan
  3. 3Joists with spacing and span arrow
  4. 4Moment connection in the lateral frame
Resists
Horizontal loads from wind and earthquakes
Vertical elements
Shear walls, braced frames, and moment frames
Horizontal elements
Floor and roof diaphragms, collectors, and chords
Code terms
Seismic force-resisting system and main wind force resisting system in ASCE 7
Not the same as
The gravity system, which carries vertical loads
Documented on
Structural general notes and framing plans

Definition

Lateral force resisting system

Wind pushes sideways on a building and an earthquake shakes its base, so the structure needs a deliberate route for those horizontal forces. The lateral force resisting system, or LFRS, is that route. It has three connected parts. Floor and roof diaphragms collect the force where it arises. Vertical elements, which are shear walls, braced frames, or moment frames, carry it down the height of the building. The foundation transfers it into the ground. Collectors and chords tie the pieces together. Building codes use two related terms: the seismic force-resisting system for earthquake loads and the main wind force resisting system for wind. One structure often uses the same elements for both.

In depth

The load path from roof to ground

A lateral load starts as wind pressure on the facade or inertia in the mass of the floors. The facade or the floor deck passes it into the diaphragm, which acts like a deep horizontal beam spanning between the vertical elements. Collectors, sometimes called drag struts, gather the force along the diaphragm and deliver it into the walls or frames. The vertical element carries it to the foundation, and the foundation resists sliding and overturning.

A break anywhere in that chain is a problem, even when every member is strong. A shear wall that stops at the second floor, a diaphragm opening that cuts off a collector, and a frame column that lands on a transfer girder each change how the force travels.

The main types of vertical system

Shear walls are solid walls of reinforced concrete, masonry, or wood or cold-formed steel with sheathing. They are stiff and take force along their length. Braced frames add diagonal members to a steel frame so that force travels as tension and compression through the braces. Moment frames use rigid beam-column connections that bend, which leaves openings free of walls but typically makes the building more flexible.

ASCE 7 lists seismic force-resisting systems in groups such as bearing wall systems, building frame systems, moment-resisting frame systems, and dual systems, each with ordinary, intermediate, and special versions where applicable. A dual system combines moment frames with shear walls or braced frames.

What the code attaches to the choice

In ASCE 7, each seismic force-resisting system has a response modification coefficient, an overstrength factor, and a deflection amplification factor. These set the design forces and the drift the building must be checked for. The seismic design category determines which systems are permitted at a given height.

The choice also has detailing consequences. A special moment frame calls for stricter connection and member detailing than an ordinary one, and the specifications and special inspection requirements follow from that choice.

Where the system is documented

The International Building Code requires the construction documents to state the seismic design data, including the basic seismic force-resisting systems, the design base shear, and the analysis procedure, and the basic design wind speed for wind. The structural general notes carry these. Framing plans mark the shear walls, braced bays, and moment connections, and details show the connections and collectors.

Architectural and MEP sheets matter too. A door cut into a shear wall, a duct through a brace, or a slab opening beside a collector can change the system the engineer designed.

What review looks for

A plan reviewer or a coordinator checks that the system named in the notes is the system drawn on the plans, that the walls and frames continue down to the foundation, and that the openings on other disciplines’ sheets do not break the load path.

The check is a comparison across structural sheets, architectural plans, and the general notes. It is tedious and easy to miss when drawing sets change between revisions.

Examples

Lateral force resisting system on a real project

  • 01

    A five-story wood apartment building resists lateral loads with plywood shear walls stacked above a concrete podium.

  • 02

    A steel office building uses concentrically braced frames at its core and perimeter moment frames.

  • 03

    The structural notes name a special reinforced concrete shear wall system, and the framing plan shows the walls that carry it.

FAQ

Frequently asked questions

A lateral force resisting system is the set of structural elements, such as shear walls, braced frames, moment frames, and diaphragms, that carries horizontal wind and earthquake loads to the foundation.

The main vertical types are shear walls, braced frames, and moment frames. ASCE 7 groups seismic force-resisting systems into categories such as bearing wall systems, building frame systems, moment-resisting frame systems, and dual systems.

The gravity system carries vertical loads such as the weight of floors and occupants down to the foundation. The lateral system resists horizontal loads from wind and earthquakes. Some elements, such as walls, work in both.

A diaphragm is a floor or roof that acts as a horizontal beam, collecting lateral forces and delivering them to the shear walls, braced frames, or moment frames.

The structural general notes state the system and the design data, the framing plans mark the shear walls, braced bays, and moment connections, and the details show the connections and collectors.